safe operation of carbon dioxide cylinders
1. Check whether there is gas leakage before use, you can apply soap to check, adjust until there is no gas leakage before carrying out the experiment.
2. When using, first open the main switch of the cylinder counterclockwise, observe the reading of the high pressure meter, record the total carbon dioxide pressure in the high pressure cylinder, and then turn the pressure adjustment screw of the low pressure meter clockwise, so that the compression main spring will open the valve. The imported high pressure gas and the high pressure gas chamber enter the low pressure chamber after being throttled to feel the pressure, and the inlet and outlet lead to the studio. After use, turn off the main switch of the cylinder clockwise first, and then loosen the pressure reducing valve counterclockwise.
3. To prevent the use of the cylinder temperature is too high, the cylinder should be stored in a cool, dry, away from heat source, not more than 31 degrees.
4. Cylinders cannot be placed lying down. If the cylinder is lying down and the pressure reducing valve is opened, the carbon dioxide liquid rushed out is quickly vaporized, and the accident of pipe burst and a large amount of carbon dioxide leakage is easy to occur.
5. The pressure reducing valve joint and the pressure regulator device are correctly connected and have no leakage and no damage.
6. The old cylinder shall be inspected regularly. After the safety standard life of the cylinder is exceeded, it can be continued to be used after the pressure test is passed.