open the valve to pressurize the regulator, or you may damage the equipment. Do not open the H cylinder with any tools, but by hand. If the valve won't open, the tank is faulty.
Medical gas cylinders must be hydrostatically tested every five years. The date of each test is engraved directly on the bottle. Before filling gas cylinders, check to make sure they are not being tested. (How to Fill and Transport Oxygen Cylinders)
NOTE: Most H cylinders used in hospitals are equipped with liquid oxygen storage decanters.
Before filling HP cylinders
Check the valve opening for any debris and remove any debris (if there is any pressure inside, it is usually just a matter of "opening" the cylinder hard and briefly); if debris cannot be easily removed, mark it as OOS (out of service ) and report the cylinder number to FAO (Food and Agriculture Organization).
Inspect gas cylinders for damage, corrosion, illegal repairs, or improper marking. Check valves and regulators, if any; make sure they are within specification and in good condition.
If you are not sure about the program or something happened that you did not expect, stop the program and contact your supervisor or other qualified person before continuing. The potential for explosions can make this mission very dangerous if not executed properly.