1. Production conditions of oxygen valve
GB16912-2008 "Safety Technical Regulations for the Production of Oxygen and Related Gases by Deep Freezing" makes the following provisions on the selection of oxygen valves.
(1) The valve of the oxygen pipeline should be a professional oxygen valve and should meet the following requirements:
a. Oxygen pipelines with working pressure greater than 0.1MPa are strictly prohibited from using gate valves;
b. Manual oxygen valves whose nominal pressure is greater than or equal to 1.0 MPa and whose nominal size is greater than or equal to DN150 should choose a valve with bypass;
c. The selection of valve materials should meet the
Valve material selection requirements
Working pressure P/MPa Material P≤0.6
1. The valve and valve cover are made of malleable iron, ductile iron or cast steel
2. The valve stem is made of stainless steel
3. The valve disc is made of stainless steel
①0.6
②P>10 choose copper alloy), nickel and nickel-based alloy.
Note: 1. The material of the pressure or flow regulating valve whose working pressure is above 0.1MPa should be stainless steel or copper alloy or a combination of the above two.
2. The sealing packing of the valve should be made of polytetrafluoroethylene or flexible graphite material.
(2) For oxygen valves whose nominal pressure is greater than or equal to 1.0MPa and whose nominal size is greater than or equal to DN150 diameter, pneumatic remote control valves should be used.
Second, the type of oxygen valve
Oxygen special valve, oxygen special stop valve, bevel gear oxygen special stop valve, oxygen special check valve, oxygen special ball valve, oxygen special butterfly valve, oxygen special pressure reducing valve, oxygen flame arrester, oxygen filter, oxygen pneumatic shut-off valve, oxygen regulating valve.
3. Structural Factors of OxygenValve
①The switch part of the globe valve moves straightly on the valve seat, and the load of its sealing surface can be reliably controlled by the valve stem with trapezoidal transmission thread. With the help of the design of the valve disc and the valve seat, the friction force of the valve disc on the valve seat can be very small or not even during the movement, which solves the friction problem of the sealing pair during the opening or closing of the valve.
② In the structural design of the globe valve, the flow of the medium must be considered to make it flow smoothly and reduce the strong impact formed. The surface of the inner cavity of the flow channel through which the flow rate of the oxygen medium passes should be smooth, smooth, without edges and corners, sharp corners, and without unevenness. There is no sudden change, the acute angles of the internal parts of the valve are blunt and rounded, and the valve stem relief groove should be rounded to ensure that there is no sudden change in the pressure of the medium during the flow process, no sudden change in the direction of the flow rate, and there can be no solid objects in the cavity of the valve body. Prevent static electricity.
③The design of the disc and valve seat geometry of the globe valve is spherical-conical. The contact between a spherical surface and a conical surface is theoretically a line contact, but in fact it is a very narrow sealing belt, which can be achieved under low load. design stress. The spherical-conical structure, after the valve is closed, has a force component that resists lateral movement due to vibration. The spherical valve disc can rotate within a certain range on the conical valve seat, and it is automatically corrected to ensure good sealing performance.
④In order to make the globe valve achieve good sealing performance, the movement of the valve disc is guided structurally so that it can accurately land on the valve seat. When the wide disc is guided in the valve body, the valve disc is pushed laterally by the flowing medium. The force is borne by the valve body rather than by the valve stem, which further increases sealing performance and the possibility of packing seals.
⑤ The connection between the valve disc and the valve stem of the globe valve is a hinge type. Its biggest advantage is that it can automatically adjust the centering position of the valve disc and reduce the friction between the valve disc and the valve seat during movement, and its sealing performance can be easily guaranteed.
⑥ The valve stem of the globe valve is designed as a lifting rod, that is, when the valve stem rises and falls
If the valve does not rotate, the valve disc moves up and down with it, which reduces the friction between the valve disc and the valve seat when it moves, reduces the wear of the packing, and at the same time, the wear of the upper seal may also be reduced to a minimum.
⑦The stem nut of the globe valve is closed with a metal cover to isolate the stem nut from the atmosphere, preventing dust from adhering to the stem nut, and entering the lower part of the stem through the trapezoidal thread, so as to enter the stuffing box during the lifting of the stem , The lubrication of the bracket bearing should be fluorinated grease.
⑧There are grounding bolts on the end flange of the valve body for oxygen special valves, and they are connected by wire bolts to avoid explosion accidents caused by sparks caused by static electricity.
⑨The exposed part of the valve stem of the oxygen-specific ball valve and globe valve should be protected against dust and oil. A plexiglass cover is installed at the frame of the bracket, and there is an obvious "no oil" sign to remind the on-site personnel to pay attention.
4. Medium Flow Direction
The medium of the T-shaped globe valve flows in and out from the valve seat, and closing the valve can only be achieved after the valve seat is forcibly "covered" with the valve disc. Since the closing or opening of the globe valve is realized by the disc acting on the valve stem overcoming the dynamic pressure and static pressure on the front (or back) of the medium, the closing and opening torque of the globe valve is greater than that of the same pressure level and the same nominal size. Gate valve, the valve stem is stressed. Therefore, the medium flow direction of the T-shaped globe valve with small nominal size mostly enters from below the valve disc of the stop valve and then flows out from the top of the valve disc, that is, the medium flows in the "low in and high out" flow direction. Medium and large nominal size T-shaped globe valve, the nominal pressure is PN16~40 (or CL150~3001b), the nominal size is not less than DN100, or the nominal pressure is not less than PN64 (or CL>4001b), and the nominal size is not less than DN80. The flow direction of the medium adopts the flow direction that enters from the top of the valve seat and valve disc of the globe valve, and flows out from the bottom of the valve seat and valve disc, that is, the medium is high in and low out. And mark the medium flow direction of the valve on the obvious part of the valve body.
Special valves for oxygen pipelines must be safety-oriented. There are special requirements in the selection of valve types, structural design, and selection of valve body materials. At the same time, strict degreasing, anti-static, oil-free and related inspections are required.